electrohydrodynamic mini flowmeter
email: porter@microflowmeter.com Shanghai JSNMicro Flow Meter CO.,LTD is a famous manufacture who produces instruments. Itwas founded by previous Siemens engineer, Mr Stone. He devoted himself into mircoflow meter,oval gear flow meter ,coriolis mass flow meter,electromagnetic flowmeter,piston flow meter,spur gear flow meter,gear pump,gear metering pump. Ourflow meters have already occupied not only large market but our clients’hearts. JSN has already been the pronoun of automation instruments. We not onlyoffer you processing-control instruments that with high quality but also offeryou one-stop service. We are always your professional support and guarantee.Our delivery is within 3-7working days. If you have special requirments, we cancustomize for you based on your parameters and the delivery time is about 3-4weeks.

electrohydrodynamic mini flowmeter
Withthe development of society, the state pays more and more attention to theprocess automation instrumentation industry. However, the Oval gear flow meter industryhas been in a vacancy and has been monopolized by major foreign brands such asMax, KRACHT, OVAL, etc. , People have long endured the expensive, longdelivery, the sale can not be resolved in time and so on, such as semiconductorchip cutting a set of equipment on the millions, once the instrument problems,loss unimaginable, the slayer saw these phenomena, Resolutely resigned assenior engineer in the position of Siemens, the establishment of ShanghaiJi-sheng Instruments Co., Ltd., with great concentration on research anddevelopment of gear flow meter. We have Oval gear flow meter has been awarded anumber of certificates, it is no exaggeration to say that Qishen production Ovalgear flow meter For example, many customers replace the OVAL LSF40 with ourCX-M5-AL because it costs less than half of the LSF40, but has twice the rangethan it does and has the same accuracy.
Oval gear flow meter, belonging to a type of volumetric flowmeter,cylindrical shape, with import and export, according to the media with a customfilter. Small size, light weight, easy installation, compact structure, withouttoo much maintenance; other The range ratio is very wide, generally more than1: 100, the minimum flow rate can be measured to 0.3ml / min; and thelinearization accuracy can reach 0.5% FS of full scale, so the use is very wideand can be used for measuring, regulating, controlling and distributing Highand low viscosity, or corrosive liquids, and there are health-type,explosion-proof for a special environment.

electrohydrodynamic mini flowmeter
The ovalgear flow meter"s metering principle is the same as that of a generalvolumetric flow meter. The gears mesh with the fluid to be transported. Thefluid to be measured enters the chamber through the oil inlet and pushes therotor so that the fluid is continuously divided into the same volume of fluid.Oil port output. For every one rotation of the rotor, the flowmeter outputs thesame volume of fluid in the four metering chambers in the figure. By measuringthe number of revolutions of the elliptical gear rotor, the volume flow throughthe fluid can be obtained.

electrohydrodynamic mini flowmeter
Maintechnical data of JSN micro oval Oval gear flow meter
CX-M2,flow range :0.5~150ml/min,accuracy 0.5%,G1/8"
CX-M3, flowrange:3~300ml/min,accuracy 0.5%,G1/8"
CX-M5, flowrange:5~1000ml/min,accuracy 0.5%,G1/8"
CX-M6, flowrange:0.5~100L/H,accuracy 0.5%,G1/4"
CX-M9, flowrange:6~600L/H,accuracy 0.5%,G1/4"
CX-M12,flow range:0.3~30L/Min, accuracy 0.5%,G1/2"
CX-M25,flow range:0.5~100L/Min, accuracy 0.5%,G1"
Oval gear flow meter knowledge:As a volumetric flowmeter, the tiny Oval gear flow meter has relatively low requirements for the front and rear straight pipe sections, and basically no straight pipe section requirements. The turbine flowmeter, as a speed flowmeter, has relatively high requirements for the front and rear straight pipe sections, especially for small diameter ones. Turbine flowmeter must be equipped with a corresponding section of straight pipe. Because of different internal structures, turbine flowmeters tend to generate eddy currents if they are installed too close to the bend pipe, affecting the internal impeller and affecting the accuracy of the flowmeter.